Request Information - The Rowland Co.
The Rowland Company
Krupp, Liebherr and Demag Crane brake drums
Crane brake lining and rivets
Back to The Rowland Company Home Universal Joints Flexible Couplings Clutches & Brakes Gear Units Friction Materials Variable Speed Drives Crane Electrification
The Rowland Company is the oldest industrial distributor in the City of Philadelphia, PA.
 Search Catalog
      GO   
 All Categories    Conductor Bar Data Sheet
All Categories > Conductor Bar Systems > Conductor Bar Data Sheet > Request Information  

Request Information
Enter your comments/questions and click Submit to send us an email.

In reference to:
Conductor Bar Data Sheet


 Additional Options
APPLICATION
 
1. Application Type:No Preference  Bridge    Monorail    Other    Runway    
2.No Preference  New Approved Installation?    Extended Existing?    Replacement?    
3. System Length:feet         
4. Total # of Conductors:         
Will one conduct be designated as a ground?No Preference  No    Yes    
ENVIRONMENTAL DATA
 
1. Describe the environment where the conductor system will be located:No Preference  
Both Indoors and Outdoors  
Indoors  
Outdoor & Ice  
Outdoors  
2. Ambient temperature range: MinDegrees F         
Ambient temperature range: MaxDegrees F         
3. Will a heater wire need to be included?No Preference  No    Yes (If Yes, consult factory)    
4. Is there a source of corrosion present?No Preference  No    Yes    
If yes, describe the corrosive:         
5. Other environmental considerations (dust, etc.)?         
MECHANICAL DATA
 
1. Vehicle Speed(feet per min.)         
Duty Cycle:         
2. Number of vehicles or trolleys:         
Crane Class (if applicable)         
3. Will we be supplying mounting brackets?No Preference  No    Yes    
4. Does the system include any curves?No Preference  No    Yes (If Yes, consult factory)    
5. Other mechanical notes:         
ELECTRICAL SPECIFICATIONS
 
1. Number of power feeds:         
2. Location of power feeds (check all that apply):No Preference  
Center  
End  
Multiple  
Advanced: Distance power feeds will be from end of system (or attach diagram):  
3. Number of power phases:         
Operating voltage:No Preference  
(volts)AC  
(volts)DC  
4. Total current draw: (sum of all vehicles )(Amps)         
Demand factor(typically .9)         
5. Operating Frequency(Hz - U.S. is 60 Hz)         
 Required Fields *

Attach File(s)
Up to 5 files for a total size limit of 10MBFile attachment
 File attachment
Your Information
Cancel
 Required Fields *
Name *
Title
Company
Address Line 1
Address Line 2
City
State
Zip/Postal Code
Country
Phone Number
Fax Number
Email *
Send Copy to Self
Remember my Information
Comments
Cancel
Back to The Rowland Company Home